1.
Appl Radiat Isot ; 117: 123-127, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26778764

RESUMO

The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine internal monitoring of occupationally exposed individuals. The determination of photon emitting radionuclides in the human body requires calibration of the detector in specific counting geometries. The calibration process uses physical phantoms containing certified activities of the radionuclides of interest. The objective of this work was to obtain calibration efficiency curves of the Whole Body Counter in operation at the LDI/CDTN using a BOMAB physical phantom and Monte Carlo simulations.


Assuntos
Método de Monte Carlo , Radioisótopos/análise , Radioisótopos/normas , Software , Contagem Corporal Total/instrumentação , Contagem Corporal Total/normas , Brasil , Calibragem/normas , Análise de Falha de Equipamento/normas , Humanos , Laboratórios , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Reprod. clim ; 25(1): 16-18, 2010. ilus
Artigo em Português | LILACS | ID: lil-651144

RESUMO

A esterilização feminina não cirúrgica por meio da aplicação intracervical de pastilhas de cloridrato de quinacrina foi considerada um método contraceptivo definitivo de baixo custo, seguro e eficaz. O zinco, presente no útero e nas tubas uterinas, inibe a ação da quinacrina. A adição de cobre aumenta a eficácia da quinacrina, reduzindo o risco de gravidez devido às falhas de obstrução das tubas uterinas. O cobre neutraliza o efeito deletério do zinco, aumentando a eficácia do método. Para obter o mapeamento da concentração de zinco no aparelho reprodutor feminino, amostras de útero e de tubas uterinas foram analisadas por ativação neutrônica instrumental. Os resultados obtidos são apresentados neste trabalho.


Nonsurgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The zinc, present in both uterus and Fallopian tubes, inhibit the action of quinacrine. The addition of copper increases the efficacy of quinacrine, thus reducing the risk of pregnancy due to the failure to obstruct the Fallopian tubes. The copper neutralized the deleterious effect of the zinc and so the treatment efficacy is increased. In order to obtain a mapping to study the zinc concentration in the female reproductive system, samples of both uterus and Fallopian tubes were analyzed by neutron activation. The results are here reported.


Assuntos
Humanos , Feminino , Cobre , Esterilização Reprodutiva/métodos , Implantes de Medicamento/uso terapêutico , Quinacrina/efeitos adversos , Zinco
3.
Reprod. clim ; 24(2): 66-70, 2009. ilus
Artigo em Português | LILACS | ID: lil-648023

RESUMO

Objetivo: A esterilização feminina não cirúrgica por meio da aplicação intracervical de pastilhas de quinacrina foi considerada um método contraceptivo definitivo, de baixo custo, seguro e eficaz, e é sabido que a adição do cobre aumenta a eficácia da quinacrina. Com o objetivo de produzir pastilhas de cobre a serem aplicadas juntamente com pastilhas de quinacrina, foi desenvolvido, no Centro de Desenvolvimento daTecnologia Nuclear da Comissão Nacional de Energia Nuclear (CDTN/CNEN), um processo para sua fabricação. Material e métodos: Utilizou-se póde cobre metálico esferoidal e amido de milho e empregaram-se as mesmas técnicas de metalurgia do pó empregada na fabricação de pastilhas combustíveis nucleares. Resultados: Foi possível definir o teor ideal de amido de milho para diminuir o intertravamento entre as partículas metálicas de cobre que propicia uma adequada desagregação das pastilhas quando umidificada, de modo a criar no útero um ambiente rico em cobre antes da dissolução das pastilhas de quinacrina. Conclusões: Foram, então, produzidas 200 pastilhas de cobre com 6% em peso de amido de milho, para viabilizar um projeto de pesquisa da Faculdade de Medicina da Universidade Federal de Minas Gerais sobre esterilização feminina não cirúrgica com quinacrina. São descritas as técnicas, os testes e os resultados do desenvolvimento desta metodologia.


Objectives: Non-surgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The addition of copper increases the efficacy of quinacrine, reducing the risk of pregnancy due to a failure in the obstruction’s procedure of the Fallopian tubes. In order to produce copper pellets to be applied together with the quinacrine pellets, a manufacturing procedure was developed at Centro de Desenvolvimento da Tecnologia Nuclear da Comissão Nacional de Energia Nuclear (CDTN/CNEN). Material and Methods: It was used spheroidal metallic copper and corn starch and the same technics of powder metallurgy employed to the fabrication of nuclear fuel pellets. Results: It was possible to defi ne the ideal corn starch content to decrease the interlock degree between the metallic copperparticles that provide an appropiate desintegration of the pellets when humidfied in order to create in the uterus an environment rich in copper before the quinacrine pellet dissolution. Conclusions: Two hundred copper pellets were produced with 6% by weight of corn starch to make possible a research project of Faculdade de Medicina of Universidade Federal de Minas Gerais about non-surgical female sterilization with quinacrina. The techniques, tests and results of the developed methodology are here presented.


Assuntos
Cobre , Esterilização Reprodutiva/métodos , Dispositivos Intrauterinos , Implantes de Medicamento/uso terapêutico , Quinacrina/efeitos adversos , Zinco
4.
Radiol. bras ; 40(5): 331-336, set.-out. 2007. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-467769

RESUMO

OBJETIVO: A análise crítica da metodologia de medida da camada semi-redutora em feixes de raios X teve como base o regulamento técnico para proteção radiológica e controle de qualidade em radiodiagnóstico médico e odontológico. MATERIAIS E MÉTODOS: Na medida da camada semi-redutora, a técnica radiográfica, o arranjo experimental, os meios espalhadores, a instrumentação, o tamanho de campo de radiação e a metodologia de análise dos dados foram considerados. RESULTADOS: A camada semi-redutora obtida em condições de boa geometria, para a técnica escolhida, foi de 2,44 ± 0,02 mmAl. Em relação a este valor, observaram-se desvios máximos na camada semi-redutora de 4,1 por cento na variação da geometria, de 98,8 por cento na variação da câmara de ionização e do meio espalhador, e de até 29,5 por cento com outro tipo de detector. CONCLUSÃO: Os resultados mostraram que não ocorre variação significante na camada semi-redutora para diferentes tamanhos de campo de radiação, mas foram evidentes a influência do espalhamento na superestimação da camada semi-redutora e a redução desta na presença de blocos de chumbo como meio espalhador. O procedimento prático adotado mostrou-se bastante confiável e evidenciou a grande discrepância decorrente da adoção de metodologias impróprias, enfatizando a necessidade de estabelecer um procedimento padrão para a medida da camada semi-redutora.


OBJECTIVE: The critical analysis of the methodology for evaluating the x-ray beam half-value layer was based on technical standards for radiological protection and quality control in medical and dental diagnoses. MATERIALS AND METHODS: Exposure parameters, experimental set-up, scattering materials, instrumentation, size of radiation field and methodology of data analysis have been taken into consideration for measurements of half-value layer. RESULTS: The half-value layer, in good geometry, measured 2.44 ± 0.02 mmAl. A maximum deviation of 4.1 percent was found under other geometry conditions. A 98.8 percent deviation was observed with a different ionization chamber, and scattering material, and 29.5 percent with another type of detector. CONCLUSION: Results showed that no relevant variation is observed in the half-value layer for different radiation field sizes. On the other hand, the influence of the radiation scattering on the half-value layer overestimation was clearly observed, as well as the half-value layer reduction in the presence of lead used as scattering material. The practical methodology adopted for half-value layer evaluation has shown to be quite reliable, besides evidencing remarkable discrepancies resulting from the adoption of inappropriate methodologies, emphasizing the necessity of establishing a standard procedure for measuring the half-value layer.


Assuntos
Proteção Radiológica/métodos , Radiologia/instrumentação , Radiologia/normas , Radiometria/métodos , Tecnologia Radiológica , Doses de Radiação , Controle de Qualidade , Proteção Radiológica